A PHP Error was encountered

Severity: Warning

Message: fopen(/opt/alt/php74/var/lib/php/session/ci_sessiond5b39da9b34ae7dab85445e3968f430c026939e0): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 178

Backtrace:

File: /home/zytroni1/public_html/cozimed.com/application/controllers/Home.php
Line: 6
Function: __construct

File: /home/zytroni1/public_html/cozimed.com/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /opt/alt/php74/var/lib/php/session)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/zytroni1/public_html/cozimed.com/application/controllers/Home.php
Line: 6
Function: __construct

File: /home/zytroni1/public_html/cozimed.com/index.php
Line: 315
Function: require_once

Mobile X-ray machine KMX-B102 | by Cozimed

Generate Catalog For :

Mobile X-ray machine KMX-B102

Download Catalog

Overview

Mobile X-ray machine KMX-B102 is an advanced x-ray imaging modality designed for better mobility and manageability during intra-hospital transit. System is equipped with 50 pre-set exposure programs with automatic back-up memory and multiple protection functions for safer use. Automatic self-test setting and alarming reduces need for maintenance. Proximal as well as remote accessibility controllers make it more versatile to use.

Features

High frequency X-ray generation

High quality X-ray monolight technology

Exposure current: 1.0-180mAs (46 steps)

50 built-in exposure control programs

Accurate X-ray penetration

Flexible and easy source orientation

Symmetrical collimator

Mobile table (optional)

specifications

Inverter Frequency

50 kHz

Tube Voltage

40 kV – 100 kV (interval 1 kV)

Operational Access

Wired/Wireless Control

Current

1.0–125 mAs (43 steps)

Power Rating

3.5 kVA

Internal Resistance

≤ 1 Ω

Exposure Parameters

VoltageCurrentRadiographic Density
40 kV - 49 kV63 mA1 mAs - 125 mAs
50 kV - 59 kV55 mA1 mAs - 110 mAs
60 kV - 69 kV45 mA1 mAs - 90 mAs
70 kV - 79 kV40 mA1 mAs - 80 mAs
80 kV - 89 kV36 mA1 mAs - 71 mAs
90 kV - 99 kV32 mA1 mAs - 63 mAs
100 kV - 110 kV20 mA1 mAs - 40 mAs

Power Supply

Voltage : 220 V ±10% Frequency : 50Hz

Dimensions

1220 x 900 x 1460 mm

Weight

207 Kgs

application

Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.