| Patient range |
Adult, pediatric, neonate |
| NIBP Measurement method |
Oscillometric |
| NIBP Measurement range |
0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
| NIBP Measurement mode |
Arm Measurement |
| Temperature Range |
37°C to 42°C |
| Temperature Accuracy |
± 0.5°C |
| Warm-up Time |
< 45 s (20°C to 36°C) |
| Power Consumption |
250 VA |
| Temperature Range |
37°C to 42°C |
| Temperature Accuracy |
± 1.0°C |
| Warm-up Time |
< 45 s (20°C to 36°C) |
| Power Consumption |
80 VA |
| Display |
12.1” LCD display |
| Ultrasound frequency |
1024 (1 ± 10%) kHz |
| Max output intensity |
< 10 MW/cm2 |
| FHR measurement range |
30 bpm ~ 240 bpm |
| Display |
7-inch screen |
| Waveform |
Biphasic |
| Manual with Sync mode |
2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules |
| AED mode |
Auto analyze and charge x 3 with programmable auto energy level selection. |
| Waveform |
Biphasic |
| Energy Sequence |
150 J, 200 J |
| Analysis Time |
9 seconds |
| Audio Indications |
20 distinct voice instructions |
| Display |
OLED 160 x 128 dot matrix display |
| Storage |
Built-in TF card storage for up to 2 GB |
| Standard Sensitivity |
10 mm/mV ± 5% |
| Sensitivity Shift |
≤ ± 10% |
| Control System |
Air-temp control, Skin-temp control & Humidity control |
| Display |
LED display |
| Air Temperature Control range |
25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Baby Temperature Control range |
25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Control System |
Air-temp control & Skin-temp control |
| Display |
LED display |
| Air Temperature Control range |
25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Baby Temperature Control range |
25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Control System |
Air-temp control |
| Display |
LED display |
| Air Temperature Control range |
25°C ~ 37°C |
| Baby Temperature Control range |
| Channel |
Single channel infusion |
| Volume (VTBI) |
1 ml ~ 9999.9 ml ( 0.1 ml increment) |
| Accuracy |
Flow rate: ≤ ± 3 % Mechanical: ≤ ± 2 % |
| KVO Rate |
1 ml/h (1 ml/h ~ 300 ml/h) 3 ml/h (greater than 300 ml/h) |
| Channel |
Single channel infusion |
| Infusion Volume |
0 ml ~ 9999 ml ( 0.1ml increment) |
| Infusion Rate |
0.01 ml/h ~ 1200 ml/h (0.01ml/h increment) |
| KVO Rate |
0.01 ml/h – 5 ml/h |
| Tidal Volume |
20 ml ~ 500 ml |
| Standard Ventilation Mode |
VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH |
| Application |
Adult/ Pediatric Invasive |
| Pressure Range |
5 mbar ~ 80 mbar |
| Tidal Volume |
10 ml ~ 300 ml |
| Standard Ventilation Mode |
CMV, IMV, CPAP, Manual |
| Application |
Pediatric |
| Inspiratory Flow |
3 L/min ~ 20 L/min |
| Tidal Volume |
20 ml ─ 2500 ml |
| Configurations |
Trolley or Ceiling Pendant |
| Respiratory Rate |
1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) 4 bpm ─ 100 bpm ( VCV/PCV/PRVC) |
| Psupport |
0 kPa ─ 6 kPa |
| Control System |
Microprocessor based temperature control system |
| Control Modes |
Preheat, Manual and Skin-temp mode |
| Manual : Heater output |
0-100%, 10% increments |
| Skin-temp : Control range |
25 °C ~ 37 °C |
| Vital Parameters |
|
||||||
| Display |
240 x 320 dot matrix colour TFT |
||||||
| NIBP Measurement range |
Adult: 30-255 mmHg Paediatric: 30-160 mmHg |
||||||
| NIBP Mode |
Auto, Manual, STAT |
| Vital Parameters |
3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP) |
| NIBP Measurement range |
Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg |
| NIBP Mode |
Manual, Auto |
| NIBP Parameters |
Sys, Dia, MAP |
| Standard Parameter |
5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
| Patient Groups |
Neonate, Pediatric, Adults |
| Trace |
9 waveform (ECG,SpO2, RESP) |
| ECG Lead Mode |
5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
| Light Source |
8 Blue LED lights |
| Wavelength |
450 to 475nm |
| LED Lamp-life |
1,00,000 hours |
| Intensity Control |
Low : 25 ~ 35 μW /cm2/nm High : 35 ~ 55 μW /cm2/nm |
| Type |
Adult |
| Stroke volume |
800 ml |
| Resuscitator volume |
1630 ml |
| Bag reservoir volume |
2000 ml |
| Type |
Pediatric |
| Stroke volume |
350 ml |
| Resuscitator volume |
680 ml |
| Bag reservoir volume |
1600 ml |
| Type |
Neonatal |
| Stroke volume |
150 ml |
| Resuscitator volume |
250 ml |
| Bag reservoir volume |
600 ml |
| KVO Rate |
0.1 – 5ml/h (steps : 0.1ml/h) |
| Injection Compliance |
Adaptable for 5 syringe sizes |
| Preset Volume Range |
0.1 ml – 1999.9 ml |
| Occlusion System |
3-level alarming system |
| Channel |
Single channel infusion |
| Volume (VTBI) |
0 ml – 9999 ml |
| Injection Compliance |
Adaptable for 6 syringe sizes |
| Accuracy |
≤ ±2 % |
| Channel |
Dual channel infusion |
| Volume (VTBI) |
0.1 ml – 1999.9 ml |
| Injection Compliance |
Adaptable for 10 syringe sizes |
| Accuracy |
≤ ± 3 % |
| Tidal Volume |
0 ml – 1500 ml |
| Gas Supply |
O2, 0.28 to 0.6 MPa |
| Ventilation Modes |
A/C, SIMV, SPONT, Manual, VCV+SIGH |
| Respiratory Rate |
4 bpm – 40 bpm (SIMV) 4 bpm – 99 bpm (A/C) |