Dialyzer Reprocessing Machine KDR-A101 is an advanced dialyzer reprocessing unit equipped with touch panel control LCD screen to select various functional settings for automated reprocessing. Specialized concentration detection system delivers optimal amount of disinfectant and ensures safe disinfection process. The reprocessing system complies with several quality factors to achieve accurate ultra-filtration standards at minimal water usage.
Cycle time | 12 minutes per cycle |
Volume test range | 0 mL to 150 mL ( ±3 % ) |
Operational Workstation | Double |
Minimum Water inlet Flow | 1.5 L/min |
Water input temperature | 10 °C to 40 °C |
Water input pressure | 0.15 MPa to 0.35 MPa |
Power consumption | 150 W |
Operation temperature | 5 °C to 40 °C |
Storage temperature | 5 °C to 40 °C |
Power supply | AC 220 V ±10 %, 50/60 Hz |
Dimensions | 480 ×380 ×580mm |
Weight | 35 Kgs |
Used in nephrology (AKD) departments in hospitals or Kidney dialysis centers to effectively automate reprocessing activities detect blood volume as well as inspect for dialyzer compliance with hospital infection-control measures for reuse of the dialyzer unit and provide recorded patient data for record keeping and quality control.
Cycle time | 12 minutes per cycle |
Volume test range | 0 mL to 150 mL ( ±3 % ) |
Operational Workstation | Double |
View Products | View Catalog |
Cycle time | 12 minutes per cycle |
Volume test range | 0 mL to 150 mL ( ±3 % ) |
Operational Workstation | Double |
View Products | View Catalog |
Cycle time | 12 minutes per cycle |
Volume test range | 0 mL to 150 mL ( ±3 % ) |
Operational Workstation | Double |
View Products | View Catalog |